AmpliTrim

16S › Dataset 5 of 11

DS05 ZymoBIOMICS D6300 (Braun 2026), 16S V3-V4

Mock communityIndependent test16S V3-V4

Marker, region, platform
16S, V3-V4 (341F/805R), NovaSeq 6000, 2x250, primers removed by the submitter, binned qualities
Samples
10
Known truth
Zymo reference sequences (8 bacteria)
How we used it
kept aside and not used in the design
Data
PRJNA1261676
Source
Braun et al., 2026
In the archive
05_mock_V3-V4_zymoD6300_PRJNA1261676
  • Pass-rate estimate off by+0.1 pointsAmpliTrim's estimate of the share of pairs passing DADA2's filter, minus DADA2's own (target: within 2 points)
  • Pass at maxEE 295%of the read pairs pass DADA2's default filter
  • AmpliTrim against FIGARO0.0 pointspairs merged with AmpliTrim's cut minus FIGARO's cut, at the same maxEE
  • maxEE the rule sets2the rule keeps DADA2's default of 2 here

How good were AmpliTrim's estimates?

SamplesPass-rate estimate off by (points)Merge estimate off by (points; mean and range)Same order as DADA2 (1.00 = identical)FIGARO's pass-rate estimate off by (points)
10+0.1+2.9 (+2.3 to +3.2)1.00+0.6

The merge estimate stops before DADA2 denoises the reads, so it is too high: use it to compare settings, not as a forecast.

AmpliTrim against FIGARO at the same maxEE

FIGARO is an automatic tool for choosing truncation lengths. A cut such as 247/199 means the forward reads are cut to 247 nt and the reverse reads to 199 nt.

SamplesFIGARO's cut and maxEEAmpliTrim's cutDifference in pairs merged (points)
10224/218, 1224/2180.0 (0.0 to 0.0)

The maxEE limit

SettingPairs merged by DADA2Change against the default (points)Against FIGARO's own cut and maxEE (points)
Default maxEE 2––+6.1
maxEE 2,5 (looser on the reverse read)–+1.5+7.6

maxEE is the most expected errors DADA2 allows in a read; reads over the limit are dropped, and DADA2's default is 2. The rule sets the limit for each read direction from your own reads, never below 2.

Change in pairs merged by maxEE 2,5 (points)Quality of the extra reads keptAccuracy (needs expected sequences)
+1.5noisieras accurate

Accuracy on this mock community

This dataset has expected sequences, so each setting can be scored.

SettingVariants foundStrains foundReads matching an expected sequence exactly
Every setting tried108 of 897.9%

Recovery of the known members

SettingSamplesExpected per sampleFound per sample (at least 0.1% of the reads / any read)In any sampleIn all samples
DADA2 Default (maxEE 2,2, No Truncation)108.08.0 (100.0%; 8 to 8) / 8.0 (100.0%)8 / 8 of 88 / 8 of 8

What the words mean: definitions. A strain is found when one of its variants is found exactly.

About this dataset

NovaSeq reads with binned quality scores; the submitter had already removed the primers. The reads are clean: 95% of the pairs pass DADA2's default filter. Every setting recovered the same 10 variants and 8 of 8 strains, with 97.9% of the reads matching an expected sequence exactly.

Where the numbers come from

docs/FINDINGS.md (the tables of sections 4.1 to 4.10) and the results folders it names, in results.