AmpliTrim

16S › Dataset 10 of 11

DS11 Mouse Gut With Spike-Ins (Qin 2025), 16S V3-V4

Real samplesIndependent test16S V3-V4

Marker, region, platform
16S, V3-V4, NovaSeq 6000, 2x250, binned qualities; mouse gut with synthetic spike-ins
Samples
12
Known truth
spike-in sequences not available, so not used
How we used it
kept aside and not used in the design
Data
PRJNA1243306
Source
Qin et al., 2025
In the archive
11_real_V3-V4_spikein_PRJNA1243306
  • Pass-rate estimate off by-0.5 pointsAmpliTrim's estimate of the share of pairs passing DADA2's filter, minus DADA2's own (target: within 2 points)
  • Pass at maxEE 288%of the read pairs pass DADA2's default filter
  • AmpliTrim against FIGARO+1.3 pointspairs merged with AmpliTrim's cut minus FIGARO's cut, at the same maxEE
  • maxEE the rule sets2the rule keeps DADA2's default of 2 here

How good were AmpliTrim's estimates?

SamplesPass-rate estimate off by (points)Merge estimate off by (points; mean and range)Same order as DADA2 (1.00 = identical)FIGARO's pass-rate estimate off by (points)
12-0.5+3.4 (+2.9 to +3.7)1.00+3.4

The merge estimate stops before DADA2 denoises the reads, so it is too high: use it to compare settings, not as a forecast.

AmpliTrim against FIGARO at the same maxEE

FIGARO is an automatic tool for choosing truncation lengths. A cut such as 247/199 means the forward reads are cut to 247 nt and the reverse reads to 199 nt.

SamplesFIGARO's cut and maxEEAmpliTrim's cutDifference in pairs merged (points)
12232/207, 2,1230/210+1.3 (+0.4 to +2.4)

The maxEE limit

SettingPairs merged by DADA2Change against the default (points)Against FIGARO's own cut and maxEE (points)
Default maxEE 2––+6.3
maxEE 2,5 (looser on the reverse read)–+2.3+8.6

maxEE is the most expected errors DADA2 allows in a read; reads over the limit are dropped, and DADA2's default is 2. The rule sets the limit for each read direction from your own reads, never below 2.

Change in pairs merged by maxEE 2,5 (points)Quality of the extra reads keptAccuracy (needs expected sequences)
+2.3noisierno expected sequences

About this dataset

Mouse gut with synthetic spike-ins; the spike-in sequences were not available, so accuracy was not assessed. NovaSeq reads with binned quality scores. At the same maxEE, AmpliTrim's cut merged 1.3 points more than FIGARO's (+0.4 to +2.4). In the first round of tests, which used a stricter margin of 1.0 point, this was beyond the margin in AmpliTrim's favour.

Where the numbers come from

docs/FINDINGS.md (the tables of sections 4.1 to 4.10) and the results folders it names, in results.