AmpliTrim

16S › Dataset 1 of 11

DS01 Mock A (Hülpüsch 2023), 16S V1-V3

Mock communityUsed in the design16S V1-V3

Marker, region, platform
16S, V1-V3 (27F-YM/534R), MiSeq 2x300
Samples
6 high-input samples for the settings (23 in the dilution series)
Known truth
the authors' ASVs anchored to Sanger sequences of 14 of 15 strains (not independent)
How we used it
used while designing AmpliTrim, so not independent evidence
Data
PRJEB67797
Source
Hülpüsch et al., 2023
In the archive
01_mock_V1-V3_mockA_PRJEB67797
  • Pass-rate estimate off by-0.8 pointsAmpliTrim's estimate of the share of pairs passing DADA2's filter, minus DADA2's own (target: within 2 points)
  • Pass at maxEE 265%of the read pairs pass DADA2's default filter
  • AmpliTrim against FIGARO0.0 pointspairs merged with AmpliTrim's cut minus FIGARO's cut, at the same maxEE
  • maxEE the rule sets2,3merging 69.5% of the pairs (default maxEE 2: 62.7%)

How good were AmpliTrim's estimates?

SamplesPass-rate estimate off by (points)Merge estimate off by (points; mean and range)Same order as DADA2 (1.00 = identical)FIGARO's pass-rate estimate off by (points)
6-0.8+2.7 (+0.3 to +4.2)0.90-0.4

The merge estimate stops before DADA2 denoises the reads, so it is too high: use it to compare settings, not as a forecast.

AmpliTrim against FIGARO at the same maxEE

FIGARO is an automatic tool for choosing truncation lengths. A cut such as 247/199 means the forward reads are cut to 247 nt and the reverse reads to 199 nt.

SamplesFIGARO's cut and maxEEAmpliTrim's cutDifference in pairs merged (points)
6273/247, 3,4273/2470.0

The maxEE limit

SettingPairs merged by DADA2Change against the default (points)Against FIGARO's own cut and maxEE (points)
Default maxEE 262.7%–-15.3
maxEE 2,5 (looser on the reverse read)76.1%+13.4-1.8
The rule (maxEE 2,3)69.5%––

maxEE is the most expected errors DADA2 allows in a read; reads over the limit are dropped, and DADA2's default is 2. The rule sets the limit for each read direction from your own reads, never below 2.

Change in pairs merged by maxEE 2,5 (points)Quality of the extra reads keptAccuracy (needs expected sequences)
+13.4noisieras accurate

Accuracy on this mock community

This dataset has expected sequences, so each setting can be scored.

SettingVariants foundStrains foundReads matching an expected sequence exactly
AmpliTrim at each maxEE tried, and FIGARO3612 of 1499.7% to 99.8%
No truncation, maxEE 23311 of 1499.8%

Recovery of the known members

SettingSamplesExpected per sampleFound per sample (at least 0.1% of the reads / any read)In any sampleIn all samples
DADA2 Default (maxEE 2,2, No Truncation)614.012.0 (85.7%; 12 to 12) / 12.0 (85.7%)12 / 12 of 1412 / 12 of 14

What the words mean: definitions. A strain is found when one of its variants is found exactly.

About this dataset

We used this dataset while designing AmpliTrim, so it is not independent evidence. It has six high-input samples. At every maxEE setting we tried, the same variants and strains were recovered, so a looser maxEE cost no accuracy here. Skipping truncation altogether merged 23.3 points fewer pairs.

Where the numbers come from

docs/FINDINGS.md (the tables of sections 4.1 to 4.10) and the results folders it names, in results.