AmpliTrim

16S › Dataset 2 of 11

DS02 Mock B (Hülpüsch 2023), 16S V1-V3

Mock communityIndependent test16S V1-V3

Marker, region, platform
16S, V1-V3, MiSeq 2x300
Samples
8
Known truth
Zymo reference sequences (three species, 7 variants; independent)
How we used it
kept aside and not used in the design
Data
PRJEB67827
Source
Hülpüsch et al., 2023
In the archive
02_mock_V1-V3_mockB_PRJEB67827
  • Pass-rate estimate off by+0.1 pointsAmpliTrim's estimate of the share of pairs passing DADA2's filter, minus DADA2's own (target: within 2 points)
  • Pass at maxEE 220%of the read pairs pass DADA2's default filter
  • AmpliTrim against FIGARO+2.6 pointspairs merged with AmpliTrim's cut minus FIGARO's cut, at the same maxEE
  • maxEE the rule sets4,8merging 70.4% of the pairs (default maxEE 2: 19.9%)

How good were AmpliTrim's estimates?

SamplesPass-rate estimate off by (points)Merge estimate off by (points; mean and range)Same order as DADA2 (1.00 = identical)FIGARO's pass-rate estimate off by (points)
8+0.1-2.2 (-6.7 to +1.1)1.00+2.9

The merge estimate stops before DADA2 denoises the reads, so it is too high: use it to compare settings, not as a forecast.

AmpliTrim against FIGARO at the same maxEE

FIGARO is an automatic tool for choosing truncation lengths. A cut such as 247/199 means the forward reads are cut to 247 nt and the reverse reads to 199 nt.

SamplesFIGARO's cut and maxEEAmpliTrim's cutDifference in pairs merged (points)
8279/248, 6,9274/253+2.6

The maxEE limit

SettingPairs merged by DADA2Change against the default (points)Against FIGARO's own cut and maxEE (points)
Default maxEE 219.9%–-54.1
maxEE 2,5 (looser on the reverse read)49.7%+29.8-24.2
The rule (maxEE 4,8)70.4%––

maxEE is the most expected errors DADA2 allows in a read; reads over the limit are dropped, and DADA2's default is 2. The rule sets the limit for each read direction from your own reads, never below 2.

Change in pairs merged by maxEE 2,5 (points)Quality of the extra reads keptAccuracy (needs expected sequences)
+29.8noisiermore accurate

Accuracy on this mock community

This dataset has expected sequences, so each setting can be scored.

SettingVariants foundStrains foundReads matching an expected sequence exactly
AmpliTrim, maxEE 263 of 368.7%
AmpliTrim, maxEE 3,563 of 374.2%
AmpliTrim, maxEE 563 of 373.6%
AmpliTrim, maxEE 4,663 of 374.9%
FIGARO, maxEE 6,973 of 378.3%
No truncation, maxEE 243 of 354.3%

Recovery of the known members

SettingSamplesExpected per sampleFound per sample (at least 0.1% of the reads / any read)In any sampleIn all samples
DADA2 Default (maxEE 2,2, No Truncation)83.02.9 (95.8%; 2 to 3) / 2.9 (95.8%)3 / 3 of 32 / 2 of 3

What the words mean: definitions. A strain is found when one of its variants is found exactly.

About this dataset

The poorest reads in the set: only 20% of the pairs pass DADA2's default filter. A looser maxEE gave a higher share of reads that match an expected sequence exactly (68.7% at maxEE 2, 73.6% to 75.2% for AmpliTrim's looser settings, 75.2% at maxEE 4,8 which is the released rule's setting, and 78.3% for FIGARO's maxEE 6,9, which also found one more variant: 7 against 6). This is the one dataset where AmpliTrim's cut differed from FIGARO's by more than the 2-point margin, by +2.6 points. In the first round of tests, which used a stricter margin of 1.0 point, it was also beyond the margin in AmpliTrim's favour.

Where the numbers come from

docs/FINDINGS.md (the tables of sections 4.1 to 4.10) and the results folders it names, in results.