16S › Dataset 3 of 11
DS03 Inter-Laboratory Mock (O'Sullivan 2021), 16S V1-V2
Mock communityIndependent test16S V1-V2
- Marker, region, platform
- 16S, V1-V2 (about 337 bp), MiSeq 2x300
- Samples
- 6
- Known truth
- none (15 bacteria; digital PCR family abundances only)
- How we used it
- kept aside and not used in the design
- Data
- PRJEB34919
- Source
- O'Sullivan et al., 2021
- In the archive
03_mock_V1-V2_interlab_PRJEB34919
- Pass-rate estimate off by-0.1 pointsAmpliTrim's estimate of the share of pairs passing DADA2's filter, minus DADA2's own (target: within 2 points)
- Pass at maxEE 296%of the read pairs pass DADA2's default filter
- AmpliTrim against FIGARO0.0 pointspairs merged with AmpliTrim's cut minus FIGARO's cut, at the same maxEE
- maxEE the rule sets2the rule keeps DADA2's default of 2 here
How good were AmpliTrim's estimates?
| Samples | Pass-rate estimate off by (points) | Merge estimate off by (points; mean and range) | Same order as DADA2 (1.00 = identical) | FIGARO's pass-rate estimate off by (points) |
|---|---|---|---|---|
| 6 | -0.1 | +0.3 (-0.1 to +0.4) | 1.00 | +0.2 |
The merge estimate stops before DADA2 denoises the reads, so it is too high: use it to compare settings, not as a forecast.
AmpliTrim against FIGARO at the same maxEE
FIGARO is an automatic tool for choosing truncation lengths. A cut such as 247/199 means the forward reads are cut to 247 nt and the reverse reads to 199 nt.
| Samples | FIGARO's cut and maxEE | AmpliTrim's cut | Difference in pairs merged (points) |
|---|---|---|---|
| 6 | 156/169, 1 | 155/170 | 0.0 |
The maxEE limit
| Setting | Pairs merged by DADA2 | Change against the default (points) | Against FIGARO's own cut and maxEE (points) |
|---|---|---|---|
| Default maxEE 2 | – | – | +2.3 |
| maxEE 2,5 (looser on the reverse read) | – | +1.4 | +3.7 |
maxEE is the most expected errors DADA2 allows in a read; reads over the limit are dropped, and DADA2's default is 2. The rule sets the limit for each read direction from your own reads, never below 2.
| Change in pairs merged by maxEE 2,5 (points) | Quality of the extra reads kept | Accuracy (needs expected sequences) |
|---|---|---|
| +1.4 | noisier | no expected sequences |
About this dataset
Six samples with no known truth (15 bacteria; only digital PCR abundances of families). The reads are clean: 96% of the pairs pass DADA2's default filter. When FIGARO was given the typical amplicon length instead of the longest, it merged 54.4% of the pairs against 93.6%.
Where the numbers come from
docs/FINDINGS.md (the tables of sections 4.1 to 4.10) and the results folders it names, in results.